|
Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Apply to: | 3s to 10slithium Ion Batteries |
| Max.Cont. Discharge Current: | 150A |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Part name: | PCM-L04S100-J99 | Size: | 190*110*11mm |
| Apply: |
12V 100Ah
12V 120Ah
12V 150Ah
|
Max. Cont. charge/discharge current: | 100A |
| Communication protocols interfaces: | 2-way UART, and RS485 | Charge & discharge share the same common port | |
| It is integrated with the smart learning style of computation coordinated with integrating Coulometer with more correct SOC of the battery. |
|||||
| Multifunctional safety protection of overcharge, over-discharge, over current, and short-circuited, temperature. |
|||||
| Battery charge and discharge over/under temperature are settable with an external NTC (103AT). The setting parameter at the same time should be uploaded to the communication Host. |
|||||
| It has a balancing function under the state of charging. | |||||
| The FET temperature is lower than 90ºC after discharging for over 1 hour at 200A under an ambient temperature of 30ºC. |
|||||
| Communication Protocol. |
No. |
Item |
Protection parameters |
Whether it can be set/Yes or No |
Noted |
|
1 |
Single-cell over Charge protection |
1-stage overcharge protection voltage | 3750±100mV | Yes |
|
| 1-stage overcharge protection delay | 2 S | Yes |
|||
| 2-stage overcharge protection voltage | 4000±100mV | Yes |
|||
| 2-stage overcharge protection delay | 2 S | Yes |
|||
Single-cell overcharge relieve |
1-stage overcharge release voltage | 3500±100mV |
Yes |
||
| 2-stage overcharge release voltage | 3500±100mV |
Yes |
|||
| Discharge relieve | I≥1000mA | Yes | |||
2 |
Single cell over discharge protection |
Stage 1 over-discharge protection voltage |
2300±100mV |
Yes | |
| Stage 1 over-discharge protection delay |
2 S |
Yes | |||
| Level 2 over-discharge protection voltage |
2000±100mV |
Yes | |||
| Level 2 over-discharge protection delay |
2 S |
Yes | |||
Single cell over-discharge relieve |
1-stage over-discharge release voltage |
2500±100mV |
Yes | ||
| 2-stage over-discharge release voltage |
2500±100mV |
Yes | |||
| Charging relieve | I≥200mA Access charger I≥ 200mA |
No | |||
3 |
OCC Charge over-current protection OCC |
Charge over-current protection current | 130±10A |
Yes | |
| Charge over-current protection delay |
2 S |
Yes | |||
Charging over-current protection relieve |
The time of OCC self-recoveries | 10 S |
Yes | REST and REST Automatically restore the locked state after 3 times, remove charger or software REST or switch REST |
|
| The number of OCC self-recoveries |
3 times | No | |||
OCC unlocked after locking |
REST REST Remove charger or software REST or switch REST |
No |
|||
4 |
OCD Discharge |
Discharge over-current 1 protection current | 200±20A |
Yes |
| 5 | Cell temperature protection |
Discharge low temperature protection delay | 2 S |
Yes |
| Discharge cryogenic protection recovery | -10±3ºC |
Yes | ||
6 |
MOS over-temperature protection |
MOS over-temperature protection OTF | 95±3ºC |
Yes |
| MOS over-temperature protection delay | 2 S |
Yes |
||
| MOS over-temperature protection recovery | 60±3ºC | Yes |
||
| 7 | Balance | Open condition |
charge | NO |
| Open voltage | 3300 mV | Yes |
||
| Turn on the differential pressure |
100 mV |
Yes |
||
| Shut off the differential pressure |
30 mV |
Yes | ||
| Balance the current | 50±5mA | No | ||
8 |
Pre-charge |
Open voltage | 2000 mV |
Yes |
| Shut off voltage | 2500 mV | Yes | ||
| Pre charge current | ≤180mA | No | ||
9 |
Pre-discharge |
Turn on the condition |
AOLD or trigger 1 time AOLD |
Yes |
| Time for pre-discharge | 5 S |
Yes | ||
| Discharge current | ≤250mA | No |



Quick Questions